416 series

Closed circuit variable displacement axial piston swashplate hydraulic pumps

 

 

 

 

Purpose:

The pumps transform the shaft rotation mechanical energy into the working fluid energy.

Hydraulic pump feed is proportional to the shaft rotation frequency and working displacement. Working displacement value is steplessly regulated from zero up to max value to each side. Fluid feed direction can be reversed by means of swash plate swivel change into the opposite side from the neutral position.

416 series pumps are intended for operation in stationary and mobile installations in set with hydrostatic transmissions (HST).

 

Working displacement: 28, 71, 90, 110, 125 ccm/rev

 

 

 

Technical characteristics:

Size

416.0.28

416.0.71

416.0.90

416.0.110

416.0.125

Working displacement Vg, ccm/rev
- min Vg min
- max Vg max

 
0
28

 
0
71

 
0
90 

 
0
110 

 
0
125 

Shaft rotation frequency n, rpm
- nominal nnom
- max nmax, at input pressure = 0.08 MPa
- peak npeak, at input pressure= 0.2 MPa

 
2000
4250
4500

 
2000
3050
3300

 
2000
3050
3300

 
2000
3000
3200 

 
2000
3000
3200 

Feed Q, l/min
- nominal Qnom
- max Qmax
- peak Qpeak

 
 53.20
113.05
119.70

 
 134.90
205.72
222.59

 
171.00
260.78
282.15

 
156.75
313.50
334.40 

 
 178.37
356.25
380.00

Boost pressure (difference) ∆P, MPa
- nominal ∆Pnom
- max working ∆Pmax
- peak ∆Ppeak

 
25
40
45 

Charge pressure Pn, МPa
- at Vg=0, nnom
- at Vg≠0, nnom

 
2.7
2.3 

Charge pump input pressure (absolute) Ps, MPa
- min working
- min short-term (t<5 min) (atidling)

 
0.08
0.05 

Drain pressure Pdr, МPa
- max working
- max short-term (t<5 min)

 
0.25
0.5

Consumed power N, kW
- nominal Nnom (at nnom, Vg max, Pnom)
- max Nmax (at nmax, Vg max, Pmax)
- peak Npeak (at npeak, Vg max, Ppeak)

 
25.08
84.71
100.77 

 
 63.5
154.1
187.3

 
 80.2
194.8
236.9

 
73.6
234.4
281.0 

 
83.6
266.1
318.9 

Driven torque T, Nm
- nominal Тnom (at Vg max, Pnom)
- max Tmax (at Vg max, Pmax)
- peak Tpeak (at Vg max, Ppeak)

 
126.61
200.88
225.64 

 
 320.68
509.01
571.79

 
404.68
643.41
722.99

 
495.30
787.09
884.35

 
561.62
893.19
1003.72 

Feed coefficient

0.95

0.95

0.95

0.95

0.95

Weight, kg

29

67

67

80

80

 

 

Design:

- variable displacement axial piston swashplate hydraulic pumps

- mounting dimensions according to DIN / ISO / SAE standards

 

Mounted in the pump end cap:

- booster pump and purge relief valve

- two check-safety valves

 

Types of control:

- proportional servo-control

- electrical proportional (12, 24 V)

- open-loop electrical proportional (12, 24 V) without feedback

- electrical discrete (12, 24 V)

- hydraulic proportional

- open-loop hydraulic proportional without feedback

 

Pumps coupling: 

- 8 mounting versions of additional pumps coupling with the base pump are available

 

Options available on request:

- filter in the booster pump pressure line, the filter is in set with the pump

- cut-off valve

- shaft rotation frequency sensor